Battery Pack Module Charge and Discharge EV Battery Life Cycle Testing System Manufacturers, Supplier in Mathura, Battery Pack Module Charge and Discharge EV Battery Life Cycle Testing System at best price in Mathura.
Input AC | AC 380V ±15%/50/60±5Hz | ||||||||||
Output Power | 24 | KW | |||||||||
Input Current | 42.9 | A/Phase | |||||||||
Input Power | 28.2 | KW | |||||||||
Voltage | CV output range | 3~60V | |||||||||
Min discharge voltage | 3 | V | |||||||||
Accuracy | ±(0.02% of FS+0.02% of RD) | ||||||||||
Stability | ± 0.1% of FS | ||||||||||
Current | Output range/channel | 0.5A~100A | |||||||||
Accuracy | ±(0.05% of FS+0.05% of RD) | ||||||||||
CV cut-off current | 0.2A | ||||||||||
Stability | ± 0.1% of FS | ||||||||||
Power | Output power/channel | 6KW | |||||||||
Stability | ±0.2% of FS | ||||||||||
Time | Current response time | Max rising time: 5ms (10% to 90% or 90% to 10%) | |||||||||
Working step time | ≤(365*24)h/step, Time format-00:00:00.000(h、m、s、ms) | ||||||||||
Data record | Data record conditions | Min data record interval:10ms (connected with AUX channel:100ms) | |||||||||
Min voltage change:0.12V | |||||||||||
Min current change:0.2A | |||||||||||
Frequency | 100Hz (connected with AUX channel:10Hz) | ||||||||||
Charge | Charge mode | Constant current, Constant voltage, Constant current and voltage, Constant power | |||||||||
Cut-off condition | Main channel:Voltage, Current, ΔTime, Capacity,-ΔV | ||||||||||
Discharge | Discharge mode | Constant current, Constant power, Constant resistance | |||||||||
Cut-off condition | Main channel:Voltage, Current, ΔTime, Capacity | ||||||||||
Pulse Mode | Charge | Constant current, Constant power | |||||||||
Discharge | Constant current, Constant power | ||||||||||
Min pulse width | 100ms | ||||||||||
Pulse cycles | up to 32 | ||||||||||
Chg and Dischg switch | Supported | ||||||||||
Cut-off condition | Voltage, Time | ||||||||||
Simulation | Charge | Constant current, Constant power | |||||||||
Discharge | Constant current, Constant power | ||||||||||
Cut-off condition | Time、Line number | ||||||||||
Continuous switching Chg and Dischg | One simulation step can realize continuous switching from charging to discharging | ||||||||||
Limit step number | 1 million | ||||||||||
Cycle | Max cycles | 65535 | |||||||||
Max steps | 254 | ||||||||||
Cycle nest | 3 | ||||||||||
Protection | ● Power-off data protection | ||||||||||
● Off-line operation mode | |||||||||||
● User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. | |||||||||||
Efficiency of Charge and discharge | >85% | ||||||||||
Protection level | IP20 | ||||||||||
Channels parallel | supported, Parallel channels do not support pulse and simulation testing | ||||||||||
Channels feature | Independent pairs of closed loop for constant | ||||||||||
Energy feedback | The discharge energy can be fed back to the grid | ||||||||||
Channels control mode | Independent control | ||||||||||
Noise | ≤65dB | ||||||||||
Database | MySQL | ||||||||||
Communicatin | TCP/IP | ||||||||||
Data export | EXCEL、TXT、CSV、PDF、Plot/Graph | ||||||||||
Disk drive | 500GB | ||||||||||
Operating system | Windows 7/8/10 64 bit | ||||||||||
Communication port | Ethernet port, CAN communication supports communication with BMS to obtain cell voltage and temperature in BMS | ||||||||||
Items | Values | ||||||||||
Number of channels | 4 | ||||||||||
Dimensions(W*D*H)(mm) | W*D*H:600*800*1300(mm) | ||||||||||
Working Environment requirement | |||||||||||
Items | Values | ||||||||||
Operation environment temperature | -10℃~45℃(When the temperature is 25±10℃, the measurement accuracy is guaranteed: accuracy drift 0.005% of FS /℃) | ||||||||||
Storage environment temperature | -20℃~50℃ | ||||||||||
Operation environment humidity | ≤70% RH(no moisture condensation) | ||||||||||
Storage environment humidity | ≤80% RH(no moisture condensation) |
Other models (Voltage and Current) | |||||
60V20A | 60V30A | 60V50A | 60V60A | 60V100A | 60V120A |
60V400A | 60V240A | 120V50A | 120V100A | 120V200A | 120V400A |
200V50A | 500V100A | 200V200A | 400V200A | 750V500A | 800V600A |
Machine equips Charge and Discharge Port or Discharge voltage below 0V is Optional | |||||
For Order Over $100
UK Orders Only
For Order Over $100