My Menu
Quick Contact
uv-lamp-environment-tester
UV lamp accelerated environment tester
Minimum
1 SET
Delivery
15 days after order.
Model
HD-E802
Country
India
BrandName
Metkorp
Package
Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual and video inside.
Payment
Online
Price
Contact for Latest Price

UV lamp accelerated environment tester Manufacturers, Supplier in Gurgaon, UV lamp accelerated environment tester at best price in Gurgaon.

Product description
Accelerated Weather UV aging test chamber simulates damaging effects of long term outdoor UV spectra of sunlight , heat, moisture on materials and coatings. It exposes specimen to varying conditions of weathering- ultraviolet radiation, moisture and heat to test the performance and improve the quality

UV Accelerated Weather chamber Usage:
Accelerated Weather Testing / UV Testing chamber is mainly used in paint and ink paint, resins, plastics, printing and packaging, aluminum, adhesives, car and motorcycle industry, cosmetics, metals, electronics, electroplating, medicine and other fields.

Technical parameters



Item

Specification

Chamber dimension (W*D*H)

1300*500*1460mm

Chamber material

SUS#304 stainless steel

Temperature range

RT to 70℃

Temperature fluctuation

≤±1.0℃

Temperature uniformity

3℃

Humidity range:

≥75%RH

Controller

Programmable controller, LCD touch screen

Control mode

Balance temperature humidity control (BTHC)

Test cycle setting

Exposure, condensation and water spray test cycle is programmable

Water spray cycle

Spray 18mins in every 120mins / spray 12mins in every 60mins

Water usage

8L/day

Distance from sample to lamp

55±2mm

Centre distance between lamps

65~70mm

Irradiance range

0.45~0.90W/m2

UV lamps

Imported Atlas UV-A: 315-400nm (8pcs, 1600h lifetime)

Lamp power

40W/Piece

Specimen Size

75×290mm (24pcs) / 75x150mm (48pcs), maximum thickness 5mm

Testing time

0~999H, adjustable

Protection system

Overload short circuit protection

Over temperature protection

Water lacking protection

Earth leakage protection

Auto shut off protection



The above parameter belongs to the standard machine section, Welcome to customize

Standard configuration
1, The installation of the UV lamp 8 on both sides of the studio;
2, The number of sample holder clamps: 20
3, The sample rack clamps Dimensions: 404 & times; 105 (mm)
4, Using the back of the scroll type drainage system and drainage U-shaped plot sinks
5, The surface of the sample and the UV lamp distance of 50 mm and a plane parallel to
6, The actual studio by the test sample holder and constitutes inside walls, trapezoidal
7, Tank water level automatic replenishment;
8, The bottom chamber can be fixed with high quality PU wheels;

Chamber structure
1, The inner bladder of the chamber is made of imported high-class stainless steel plate while the outer bladder is made of SUS 304 steel plate.
2, The heating mode adopts inner bladder trough type heating with its rapid temperature rise and even temperature distribution.

Control system
1. The use of the blackboard temperature meter control heating, the temperature is more stable.
2. Radiometer probe (optional) using fixed without each loading and unloading.
3. The amount of radiation using high-precision measurement and display of special ultraviolet radiation meter.
4. Light and condensation can be independently controlled alternating cycle control.
5. The time independent control of light and condensation control and alternating cycle time can be set in one thousand hours.
6. Automatic lighting state detection UV light, and visualize what the first few rows
7. Enables manual adjustment and automatic adjustment irradiance irradiance

Test specimen mounting
The standard test specimen holder accommodates 2 panels 75×150mm. The test panels are actual the side wall of the chamber. To properly seal the chamber, it is important to have every panel holder filled with specimens or blank panels and to have panel holders in place.

Design criteria
ISO 4892-3,ASTM G154
ASTM D4587: Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings
ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Fluorescent UV, Water Spray, and Condensation Method)
ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics
AATCC TM186: Weather Resistance: UV Light and Moisture Exposure
ASTM D5208: Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics
IEC 61345: UV Test for Photovaltalic (PV) Modules

Enquire Now

captcha
service_4_1

Worldwide Shipping

For Order Over $100

service_4_2

Affordable Pricing

UK Orders Only

service_4_5

24x7 Customer Support

For Order Over $100

Particle-Analysis-System
Microscopy Analysis
Particle Analysis System
Buy Now
Laboratory-Filtration-Unit
Millipore Assembly
Laboratory Filtration Unit
Buy Now
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
client-1
Phone
WhatsApp