Salt Spray Corrosion Chamber Manufacturers, Supplier in Andhra Pradesh, Salt Spray Corrosion Chamber at best price in Andhra Pradesh.
Applications:
Salt spray corrosion test chamber through the inspection of Solar lights, garden lights, buried lights, tunnel lights, car lights, fountain lights, the display and led lights series products and protective layer of salt fog corrosion ability.
Feature:
1, Durable hard 8 mm PVC construction, anti-corrosion and easy to clean.
2, Reservoirs with mixing system on stand.
3, Separate heating system apart from salt testing chamber to ensure accurate result and protect circuit.
4, Exposure zone lined with corrosion-resistant PVC sheets.
5, Clear cover allows viewing of test conditions.
6, Peaked cover prevents dripping of condensation onto samples.
7, Water seal and water level protection system.
8, Heated humidifying tower with air relief valve, adjustable tower tip to orient salt fog.
9, Automatic DI water fills to humidifying tower.
10, Digital temperature control.
11, Integral over-protection on heaters.
12, Low water cut-off protection on humidifying tower.
Applicable Standards:
ASTM B117, ASTM G85, ASTM D1141-98
DIN EN ISO 9227 (NSS, ESS, CASS)
DIN 50942, DIN 53 167
ASTM B 117-73, ASTM B 287-74, ASTM B 368-68
DIN EN 60068-2-11
BS 1224, BS 2011, BS3900 F4, BS 3900 F12, BS 5466 Part 1, BS 5466 Parts 2+3
NFX 41002
AS 21331 Section 3.1
SIS 1841190
JIS Z 2371
Model | HD-E808-120 |
Internal Size (W*D*H) | 1200*1000*500mm |
External Size (W*D*H) | 1900*1300*1400mm |
Equipment Material | P.V.C rigid plastic plate, thickness 8mm |
Sample tray | Diameter 10mm glass fiber rod, anti-rust V-shape plastic steel to make sure sample in 15~30 degree inclined |
Temperature Range | Room temperature ~ 55℃ |
Temperature Fluctuations | ≤±0.5℃ |
Temperature Uniformity | ≤±2℃ |
Temperature Precision | ±1℃ |
Spraying method | Continuous and Periodic spray type |
Test Chamber Temperature | Salt Spray Method (NSS ACSS)35±1℃ |
Saturated air Barrel Temperature | Salt Spray Method (NSS ACSS)47±1℃ |
Brine Temperature | 35℃±1℃ |
Spray Quantity | 1.0~2.0 ml / 80cm2 / hr |
PH value | Salt Spray Method (NSS ACSS6.5~7.2) |
Lab Volume | 600L |
Brine Tank Capacity | 40L |
Multiple Safety Protection Devices | Current discharge protection, over pressure protection, over temperature protection, over load fuse protection |
Accessories | Testing Salt/ Measuring tank/Nozzle Equipment x 1 set |
Air source | 1HP Air pump (provided by buyer) |
Test criteria | ASTM B117-08, ISO 9227... |